Equipment Design

Floating Roof Tank Design – Calculations, 3D Model and Fabrication Drawings

Our floating roof tank design covers new pontoon and double-deck roofs as well as checks of roofs already in service, with buoyancy, drainage, seals and support legs designed as one system. It sits on top of the shell, bottom and wind girder design for the tank itself.

We design external and internal floating roof tanks, pontoons, decks, roof drains, seals and support legs, and check existing floating roofs for repair and upgrade.

Also searched as: floating roof, IFR, EFR tank.

Fixed-price quote in 24 hoursSmall jobs welcomeAPI · ASME · AISC · Saudi Aramco

Last updated:

Request Engineering Support

Typical response within 24 hours · Confidentiality assured

Send us your data sheet, sketch or old drawing on WhatsApp (+966 55 545 8298) or email (enquiry@sletec.com) for a fixed-price quote, usually within 24 hours.

External floating roof or internal floating roof

An external floating roof rides directly on the product in an open-top tank, so it must handle rainfall, drainage and wind. An internal floating roof sits under a fixed cone or dome roof, which removes rainwater loads but brings vent sizing and vapour space requirements.

The choice usually comes from the product vapour pressure, emission limits and whether an existing fixed-roof tank is being converted.

API 650 Annex C and Annex H checks

Annex C governs external roofs and Annex H governs internal roofs. The table lists the main design checks we carry out.

Floating roof design checks
CheckWhat it confirms
BuoyancyRoof stays afloat at the design specific gravity, including the punctured-compartment and rainfall cases required by Annex C
Deck and pontoon strengthPlates, rim and bulkheads under live load and roof weight
Support legsLeg length and strength in low and high positions, and bottom pads to spread the load
Primary and emergency drainsDrain capacity for design rainfall, with articulated pipe or flexible hose
VentingAutomatic bleeder vents on landing; circulation vents for internal roofs
Seals and rolling ladderRim space, seal type, ladder runway and roof-to-shell clearance

Inputs we need

Tank diameter and height, product specific gravity and vapour pressure, design rainfall, the required low and high leg positions, and the seal type preferred by the operator. For existing tanks we also need shell roundness survey data, since an out-of-round shell causes seal gaps and roof jamming.

Problems found on roofs in service

We see pontoons flooded through cracked compartment welds, blocked or leaking roof drains that let product onto the deck, roofs tilting because of uneven leg settlement, and seals worn through on one side of an oval shell. Our project references include a floating-roof collapse investigation and floating-roof detailed engineering to API 650 and API 653. See also our tank FEA verification project and tank repair engineering.

How a floating roof job runs

For a new roof we agree the roof type, seal system and drain arrangement first, then issue the buoyancy and strength calculations with the roof GA. Detail drawings of pontoons, deck plates, legs, drains and rolling ladder follow. For an existing roof the work starts with inspection records and a survey of the shell, and ends with a repair scope the tank contractor can price.

Frequently Asked Questions

Can you design a floating roof tank for our project?

Yes. We prepare calculations and drawings to API 650 Annex C / H and your project specification.

Do you take small jobs?

Yes. Single drawings, one calculation or a check of an existing design are welcome.

Which countries do you serve?

Saudi Arabia, UAE, Qatar, Oman, Kuwait, Bahrain and worldwide.

Send your sketch, photo or PDF today

One drawing or a complete design package — we reply with a fixed-price quote, usually within 24 hours.

Request Engineering Support

Typical response within 24 hours · Confidentiality assured