Air Receiver Design – Calculations, 3D Model and Fabrication Drawings
Our air receiver design service produces a compressed air vessel that meets the Code, suits the compressor it serves and passes the hydrostatic test first time. We handle single receivers for a workshop and multiple receivers for a plant air or instrument air system.
We design vertical and horizontal compressed air receivers with calculations, nameplate data, GA and fabrication drawings, ready for your workshop and inspector.
Also searched as: air tank, compressed air tank.
Last updated:
Request Engineering Support
Typical response within 24 hours · Confidentiality assured
What we deliver
Send us your data sheet, sketch or old drawing on WhatsApp (+966 55 545 8298) or email (enquiry@sletec.com) for a fixed-price quote, usually within 24 hours.
Inputs for an air receiver calculation
A receiver looks simple, but a few inputs decide whether it lasts. We ask for the compressor type and capacity, because a load-unload compressor cycles the vessel far more often than a variable-speed unit, and that cycling matters for weld details.
Wet air from the compressor discharge brings condensate, so the corrosion allowance and drain arrangement are set with the site humidity and air treatment in mind.
- Required volume, or the compressor capacity and allowable pressure band so we can size it
- Design pressure and temperature, and the minimum ambient temperature for MDMT
- Vertical or horizontal arrangement, footprint and height limits
- Inlet, outlet, relief valve, drain, gauge and inspection opening sizes
- Wet or dry service, corrosion allowance and any internal lining or galvanising
ASME VIII air receiver checks
Most receivers are built to ASME VIII Div. 1, with the project or national rules added where the vessel will be registered. The table lists the checks a reviewer will look for.
| Check | What it governs |
|---|---|
| Shell and head thickness | Internal pressure plus corrosion allowance for the selected material and joint efficiency |
| Openings and reinforcement | Inlet, outlet, drain and manway or handhole reinforcement and nozzle neck thickness |
| Inspection openings | Size and number of openings needed for internal inspection under the Code |
| Overpressure protection | Relief valve set pressure and capacity relative to MAWP and compressor output (ASME Section XIII in current editions) |
| Supports | Legs, skirt or saddles under weight, wind, seismic and hydrotest load |
| Impact test exemption | Material toughness at the minimum design metal temperature |
Problems found on existing receivers
Older receivers tend to fail from the inside. Pitting along the bottom where condensate lies, a blocked or missing automatic drain, and corrosion under the drain nozzle are the usual findings. We also see relief valves set above the nameplate MAWP after a compressor upgrade, and receivers whose nameplate is lost so the design pressure is unknown.
For these cases we can recalculate the MAWP from measured thicknesses, prepare a replacement design, or produce drawings for a like-for-like vessel.
How the job runs
We confirm the design basis, issue the calculation and GA with nameplate data for comment, then release fabrication drawings and a bill of materials. If you are buying several sizes, the calculations are set up so that each size has its own complete report. Related scope is covered on our ASME pressure vessel page.
Related engineering topics
pressure vessel design, static equipment design, nozzle local stress FEA and pressure vessel FEA ASME VIII Div 2.
Frequently Asked Questions
Can you design a air receiver for our project?
Yes. We prepare calculations and drawings to ASME VIII Div. 1 and your project specification.
Do you take small jobs?
Yes. Single drawings, one calculation or a check of an existing design are welcome.
Which countries do you serve?
Saudi Arabia, UAE, Qatar, Oman, Kuwait, Bahrain and worldwide.
Related pages
Serving all GCC countries
Send your sketch, photo or PDF today
One drawing or a complete design package — we reply with a fixed-price quote, usually within 24 hours.
Request Engineering Support
Typical response within 24 hours · Confidentiality assured