Hydraulic Calculations – Line Sizing, Pressure Drop, Pumps and Surge
SLETEC prepares hydraulic calculations for line sizing, pressure drop, pump head and NPSH, and water hammer, so pipes and pumps are sized correctly before purchase and fabrication.
Pipes that are too small cause high pressure drop and noise; pipes that are too large waste money. SLETEC sizes lines and pumps correctly from the start.
We calculate line sizes, velocities and pressure drop (API RP 14E, Crane TP-410), pump head and NPSH, control valve and orifice pressure drop, water hammer and surge, and fire water network hydraulics.
Last updated:
Request Engineering Support
Typical response within 24 hours · Confidentiality assured
What we calculate (Thermal, Process and Hydraulic Calculations)
Heat transfer and duty calculation
heat transfer calculation (Excel, HTRI)
Insulation thickness and heat loss
insulation thickness (ASTM C680)
Pump sizing and NPSH check
pump size and npsh (Hydraulic Institute)
Fan and blower selection
fan / blower sizing (AMCA)
PSV sizing support
relief valve sizing (API 520 / 521)
Tank heating and cooling calculation
heating / cooling time (Excel)
Steam system calculation
steam trap / steam line (Spirax Sarco method)
HVAC load and ventilation calculation
ventilation load (ASHRAE)
Send us your drawings and data on WhatsApp (+966 55 545 8298) or email (enquiry@sletec.com) for a fixed-price quote, usually within 24 hours.
Line sizing and pressure drop calculation
Line sizing balances velocity, pressure drop and cost. For liquid lines we check velocity against erosion and noise limits and pressure drop per 100 m against the available head. For gas and two-phase lines we also check erosional velocity using API RP 14E.
Friction losses are calculated with the Darcy-Weisbach equation, with fitting and valve losses from equivalent length or resistance coefficients. The result is a line list with size, velocity and pressure drop for each segment.
Pump sizing and NPSH
We build the system curve from static head, friction losses and the required delivery pressure, then compare it with the pump curve to find the duty point. NPSH available is calculated from the suction vessel pressure, liquid level, vapour pressure and suction-line losses and compared with the pump's NPSH required plus a margin.
This check often explains cavitation or poor pump performance on existing systems and shows whether a suction-line change is enough or the pump must be replaced.
Water hammer and surge analysis
Fast valve closure or a pump trip on a long line creates pressure waves that can exceed the pipe rating and load supports heavily. We calculate surge pressures and transient forces and recommend valve closure times, surge vessels or relief protection.
Firefighting systems are a common case, because deluge valves and pump starts are sudden. Transient forces are passed to the pipe stress analysis team to check supports.
Inputs and deliverables
Every hydraulic calculation report states the fluid properties, design cases and assumptions so a reviewer can check the numbers.
| Inputs | Deliverables |
|---|---|
| P&IDs and line list | Line sizing table with velocity and pressure drop |
| Isometrics or layout with elevations | System curve and pump duty point |
| Fluid properties and flow cases | NPSH available versus required |
| Pump curves and valve data | Surge pressures and recommended protection |
Related engineering topics
piping design services, pipe stress analysis, pipe support design and pipe support calculation.
Frequently Asked Questions
Can you check if my pump is the right size?
Yes. We calculate the system curve, required head and NPSH and compare them with the pump curve.
Do you calculate pressure drop for a whole network?
Yes. We model piping networks for water, oil, gas and utilities.
Do you check water hammer?
Yes, for long lines and fast-closing valves.
Related pages
Serving all GCC countries
Send your sketch, photo or PDF today
One drawing or a complete design package — we reply with a fixed-price quote, usually within 24 hours.
Request Engineering Support
Typical response within 24 hours · Confidentiality assured