Engineering Service

Vibration Analysis – Machines, Piping, Structures and Foundations

Is a pump, pipe, platform or machine shaking too much? SLETEC finds out why and how to fix it. We use modal analysis, harmonic response, resonance checks and dynamic foundation analysis to show the natural frequencies, the cause and the right fix.

Our vibration studies cover rotating equipment bases, compressor and pump foundations (ACI 351.3, DIN 4024), piping vibration including flow-induced (FIV) and acoustic-induced vibration (AIV), small-bore connections, platforms, floors and tall stacks. We give clear recommendations such as stiffeners, supports, bracing or foundation changes, with drawings.

Fixed-price quote in 24 hoursSmall jobs welcomeAPI · ASME · AISC · Saudi Aramco

Request Engineering Support

Typical response within 24 hours · Confidentiality assured

What we calculate (Vibration and Dynamic Analysis)

Vibration analysis and troubleshooting

machine vibration problem (ANSYS, ISO 10816 / 20816)

Modal and resonance analysis

natural frequency / resonance check (ANSYS)

Machine foundation dynamic analysis

pump or compressor foundation vibration (ACI 351.3, DIN 4024)

Piping vibration analysis

pipe shaking (Energy Institute guidelines, CAESAR II)

Flow-induced vibration (FIV)

vibration from flow (Energy Institute AVIFF)

Acoustic-induced vibration (AIV)

vibration from noise in pipes (Energy Institute AVIFF)

Small-bore connection assessment

small pipe connection cracking (Energy Institute AVIFF)

Pulsation and mechanical response study support

compressor pulsation (API 618)

Structural vibration and footfall check

platform or floor vibration (AISC DG 11)

Rotor and torsional vibration check

shaft vibration (API 684)

Seismic analysis of equipment and structures

earthquake / seismic check (ASCE 7, SBC 301, UBC)

Vortex shedding analysis

wind vibration of tall stacks (ASME STS-1, EN 1991-1-4)

Send us your drawings and data on WhatsApp (+966 55 545 8298) or email (enquiry@sletec.com) for a fixed-price quote, usually within 24 hours.

Frequently Asked Questions

What causes vibration in pumps and pipes?

Common causes are resonance (natural frequency close to running speed), weak supports, unbalance, misalignment and flow or pressure pulsation. Our analysis identifies which one applies.

Can you fix vibration on an existing platform or pipe?

Yes. We model the existing structure, find the cause and design stiffeners, braces or supports with fabrication drawings.

Do you analyse machine foundations?

Yes. We do dynamic analysis of pump, compressor and fan foundations to ACI 351.3 and DIN 4024.

Send your sketch, photo or PDF today

One drawing or a complete design package — we reply with a fixed-price quote, usually within 24 hours.

Request Engineering Support

Typical response within 24 hours · Confidentiality assured