Pig Launcher and Receiver Design – Calculations, 3D Model and Fabrication Drawings
SLETEC carries out pig launcher design and pig receiver design for oil, gas and water pipelines, sizing the barrel for the longest pig you plan to run and detailing the closure, kicker and drain connections for safe operation.
We design pig launchers and receivers, including barrel, reducer, closure, supports and piping layout, with stress checks and fabrication drawings.
Also searched as: pig trap, scraper trap.
Last updated:
Request Engineering Support
Typical response within 24 hours · Confidentiality assured
What we deliver
Send us your data sheet, sketch or old drawing on WhatsApp (+966 55 545 8298) or email (enquiry@sletec.com) for a fixed-price quote, usually within 24 hours.
Inputs for pig trap design
Pig traps are sized around the pig, not the pipe. An intelligent inspection tool can be several times longer than a cleaning pig, and a trap sized only for cleaning pigs cannot accept it later.
We also need the operating philosophy: whether the trap will be manually loaded, whether multiple pigs are launched in sequence, and how the barrel is drained and vented before the closure is opened.
- Line size, design pressure, design temperature and fluid
- Pig types and maximum pig length, including future inspection tools
- Location class or design factor for the pipeline
- Closure type preference and any client-approved closure vendors
- Kicker, bypass, drain, vent, relief and pig signaller requirements
Codes for an ASME B31.4 pig launcher and related equipment
The barrel may be designed as pipeline pressure piping or as a pressure vessel, depending on the client specification. We confirm the code split at the start and keep it consistent through every calculation.
| Code | What it governs |
|---|---|
| ASME B31.4 | Liquid pipeline traps: wall thickness, fittings and design factor |
| ASME B31.8 | Gas pipeline traps: wall thickness with location class design factor |
| ASME VIII Div. 1 | Barrel and reducer when designed as a vessel; quick-actuating closure requirements |
| Client specifications | SAES / SAMSS, SABIC or ADNOC requirements for traps, closures and interlocks |
Layout and support checks
The barrel is normally one or two sizes larger than the line, joined by an eccentric reducer so the pig sits correctly before launch. We check supports for the weight of a full barrel with the heaviest pig, closure opening clearance, handling space for a pig tray, and the forces from the connecting pipeline, including thermal movement.
Problems found on existing traps
Older traps are often too short for modern inspection tools, have closures without a pressure-warning interlock, or have drains too small to empty the barrel in a reasonable time. Our project references include a pig-trap mechanical design to ASME VIII. For related scope, see static equipment design.
Deliverables
A typical package includes the design basis, wall thickness and reinforcement calculations, closure and nozzle schedule, support calculation, GA with pig tray and handling space, piping layout around the trap and a bill of materials. Isometrics for the kicker and bypass lines can be added where the connecting piping is in our scope.
Related engineering topics
piping design services, pipe stress analysis, pipe support design and pipe support calculation.
Frequently Asked Questions
Can you design a pig launcher and receiver for our project?
Yes. We prepare calculations and drawings to ASME B31.4 / B31.8, ASME VIII and your project specification.
Do you take small jobs?
Yes. Single drawings, one calculation or a check of an existing design are welcome.
Which countries do you serve?
Saudi Arabia, UAE, Qatar, Oman, Kuwait, Bahrain and worldwide.
Related pages
Serving all GCC countries
Send your sketch, photo or PDF today
One drawing or a complete design package — we reply with a fixed-price quote, usually within 24 hours.
Request Engineering Support
Typical response within 24 hours · Confidentiality assured