SLETEC provides stack and chimney design for self-supported steel stacks, guyed stacks and flare structures, checking the shell for wind, vortex shedding, temperature and corrosion and giving the foundation loads your civil team needs.
We provide structural and mechanical design support for steel stacks, chimneys and flare stacks, including wind, vortex shedding and foundation loads.
Also searched as: chimney, stack, flare.
Last updated:
Request Engineering Support
Typical response within 24 hours · Confidentiality assured
What we deliver
Send us your data sheet, sketch or old drawing on WhatsApp (+966 55 545 8298) or email (enquiry@sletec.com) for a fixed-price quote, usually within 24 hours.
Design inputs
Height and diameter are only the start. The flue gas temperature and composition decide the material, the need for a lining and the risk of acid dew point corrosion, while the site wind speed and terrain set the governing load case.
For flares, the process engineer's flare study gives the tip type, heat release and the sterile radius, which in turn sets the stack height and whether a derrick or guyed structure is needed.
- Stack height, diameter and any taper
- Gas temperature, composition and lining or insulation requirements
- Site wind speed, exposure and seismic data
- Platforms, ladders, sample ports and breeching opening sizes
- For flares: tip weight, riser size and the radiation limits from the flare study
Steel stack design codes
Stacks combine pressure-vessel style shell checks with structural dynamics, so several documents are used together.
| Code | What it governs |
|---|---|
| ASME STS-1 | Steel stack shell, openings, base ring, anchor bolts, vortex shedding and ovalling checks |
| CICIND Model Code for Steel Chimneys | Alternative chimney design method often used outside North America |
| API 537 | Flare details, tips and associated equipment |
| API 521 | Flare radiation and sizing basis set by the process engineer |
| ASCE 7 or local code | Wind and seismic loads |
Flare stack design and vortex shedding
Slender cylinders shed vortices in steady wind, and if the shedding frequency matches the stack's natural frequency the stack can oscillate across the wind. We calculate the critical wind speed and, where needed, add helical strakes or a damper, or change the shell thickness to shift the frequency. Breeching openings are checked separately, as the cut-out weakens the shell exactly where bending is highest.
Problems on existing stacks
Typical findings include thinning near the top where condensate forms, cracked strakes, loose anchor bolts and corroded platform brackets. We can assess remaining life from thickness readings and propose repairs, a new top section or a full replacement.
Deliverables and how the job runs
We issue a design basis, then the shell calculation with natural frequency and vortex shedding results, followed by the GA, shell plate layout, base ring and anchor bolt details, platform and ladder drawings and a foundation load table. For tall stacks the erection sequence and lifting points are agreed with the contractor, since a stack lifted horizontally sees bending it will never see in service.
Related engineering topics
mechanical design services, skid design, skid base frame design and machine design services.
Frequently Asked Questions
Can you design a flare stack and chimney for our project?
Yes. We prepare calculations and drawings to ASME STS-1, API 537 and your project specification.
Do you take small jobs?
Yes. Single drawings, one calculation or a check of an existing design are welcome.
Which countries do you serve?
Saudi Arabia, UAE, Qatar, Oman, Kuwait, Bahrain and worldwide.
Related pages
Serving all GCC countries
Send your sketch, photo or PDF today
One drawing or a complete design package — we reply with a fixed-price quote, usually within 24 hours.
Request Engineering Support
Typical response within 24 hours · Confidentiality assured